The spark arrestor shall meet all of the following requirements.
California chimney spark arrestor requirements.
Chimney caps and spark arrestors are available in stainless steel copper and galvanized steel.
In california orange county and los angeles county are very high fire hazard even a tiny spark can start a fire so if your home is located within a wooded area chimney caps an spark arrestor is strongly recommended.
If so you should certainly consider california spark arrestor chimney caps with small 5 8 inch mesh.
Spark arrestors are required in all blm and forest service lands.
The chart below indicates minimum arrester screen dimensions which will comply with the code.
The building inspector will need to see such spark arrester in place at the time of inspection.
The spark arrester shall be tight fitting to the chimney to prevent sparks or embers.
This is for all of the west and i m pretty sure the entire nation.
California spark arrestors must be made of 5 8 mesh and 4 times the area of the opening of the flue with 5 6 of clearance from the top of the flue to the spark arrestor covering.
Chapter 10 chimneys and fireplaces.
R1001 2 1 ash dump cleanout.
So you are not riding legally 5 miles form the border.
California state parks state of california.
Even if your locality does not require 5 8 screening or california spark arrestor chimney caps if you have an oval flue tile these are the appropriate chimney caps for your flue.
Spark arresters must comply with the california building code as adopted by the city specifically section 3102 3 8 the total area of the arrester shall be at least four 4 times the total area of the chimney area.
The spark arrestor screen shall have heat and corrosion resistance equivalent to 12gage wire 19 gage galvanized wire or 24 gage stainless steel.
Opening shall not permit the passage of spheres having a.
The net free area of the spark arrestor shall be not less than four times the net free area of the outlet of the chimney.
At the state operated riding areas it is california law but in this case it is the same as the federal regulations.
The net free area of the spark arrestor shall not be less than four times the net free area of the outlet of the chimney.
A notwithstanding section 4442 of the public resources code and except for vehicles with mufflers as provided in article 2 commencing with section 27150 of chapter 5 of division 12 no person shall use operate or allow to be used or operated any off highway motor vehicle as defined in section 38006 on any forest covered land.
R1001 2 footings and foundations.
This is federal law not california law.